Horizontal exits a solution to Egress challenges

If your facility has unique egress challenges, a horizontal exit could provide requirements for egress capacity you need.

分享皇家88账户注册篇文章

Proper egress analysis is an extremely important aspect of 消防安全设计 that not only involves following applicable codes, but also careful coordination with the project architect. International Building Code (IBC) defines an 可访问的 means of egress as a “continuous and unobstructed way of egress travel from any point in a building or facility that provides an 可访问的 route to an area of refuge, 出口:水平出口或公共通道.” Adequate means of egress can vary depending on the use of the building and the occupancy load. Facilities with large occupancy loads can present challenging egress design, specifically if the existing building is being retrofitted to accommodate a change of use to contain that larger load. Frequently, the existing exit capacity provided on each floor is not adequate for the new occupancy.

什么是水平退出? 一个定义和它如何有帮助

For facilities with large occupancy loads or those that must be retrofitted, designing and constructing a horizontal exit may be the best solution for providing the required egress capacity. Horizontal exits are designed to create a safe refuge area separated from the fire area by a two-hour fire-resistance-rated separation. It is recognized in accordance with the 2015 IBC and/or the 2015 NFPA 101, 生命安全守则.

A 现实的例子

One of our recent projects involved a new tenant space within an existing high-rise office building, which was being retrofitted to include offices and large assembly/conference areas. The tenant space had two existing exit stairs that provided a maximum exit capacity of 440 occupants. The new occupant load of the tenant space would exceed 500, requiring a third exit and additional exit capacity in accordance with the applicable codes.

为了实现皇家88账户注册个目标, we needed to maintain a separate level of security for office spaces from the assembly areas. The public would often use assembly areas for events, which meant the office areas had to be kept secure, only allowing entrance for employees by way of a swipe card. The design of the refuge area could not extend into the office spaces and had to be contained within the common areas of the building.

使用水平退出方案, we designed an exit that included a two-hour separation through the tenant space creating separate compartments with an available exit stair on each side. We based the refuge area on the capacity available by the horizontal exit doors. This horizontal exit solution solved the client’s egress dilemma efficaciously.

Designing an 可访问的 means of egress for large capacity buildings can be complex and innovative solutions can help achieve compliance and keep people safe.

你在出口方面遇到过什么挑战? 给皇家88娱乐发个便条 info@dektinary.com 或者发推特给皇家88娱乐 @jensenhughes .

更多来自Jensen Hughes的博客文章


Single- and Multi-Station Low-Frequency Audible Signaling

2023年12月27日

Carson Cook discusses the challenge posed by the 2021 IBC requirement for audible alarms activated by single- and multiple-station smoke alarms and how to meet the requirement for non-transient occupancies.

皇家88娱乐
Fire Safety Design in Semiconductor 制造业 Cleanrooms

2023年12月11日

保罗Bigatti, 消防工程师, delves into the challenges associated with integrating fire protection systems within semiconductor facilities, particularly within the controlled environments of manufacturing cleanrooms.

皇家88娱乐
Mitigating Lithium-Ion Battery Energy Storage Systems (BESS) Hazards

2023年12月8日

Battery energy storage systems (BESS) use an arrangement of batteries and other electrical equipment to store electrical energy.

皇家88娱乐